How to operate the force measuring instrument

2019-08-11

Shenzhen Anpu Measurement and Control Technology Co., Ltd.DynamometerStable and reliable performance, unique functions such as transparent calibration, automatic calibration, nonlinear correction, etc., suitable for various force measuring places; the instrument adopts serial number identification, which makes the network of the force measuring system very simple, and the analog signal input and output adopts wiring terminals to facilitate Field test; cost-effective; widely used in industrial and commercial force measurement systems in metallurgy, building materials, machinery, electronics, machine tools, testing machines and other industries.

Description of the operation mode of the force measuring instrument:

The meter is in the measurement state, press and hold the key until it is displayed, and the key enters the modification state. With the cooperation of the , and keys, it is changed to 01111, press the key, and then press and hold the set key and do not release, and enter into each parameter group in sequence. The instrument displays the symbol of the first parameter in this group, press the keys to select the parameter to be set in this group in sequence, press the key to call up the set value of the current parameter, the flashing bit is the modification bit, and the modification bit is moved by the key, the key is incremented, and the key is decreased. , modify the parameter to the required value, press the key to save the modified parameter, and go to the next parameter.

Exit setting: When the parameter symbol is displayed, press and hold the setting key until it exits the parameter setting state.

When the measured value exceeds the alarm setting value, the alarm delay is started. If the measured value is always in the alarm state during the alarm delay period, the alarm signal will be output when the alarm delay ends, otherwise the alarm signal will not be output.

EXT504

Install the clamp connecting rod, start the "1" position of the travel switch. Adjust the "coarse adjustment" knob to make the reading of the panel meter zero, and then press the "50" file. Adjust the "fine adjustment" knob to make the display meter display zero status.

Press the "calibration" block of the range switch, and adjust the "calibration" knob. Make the reading on the panel meter consistent with that specified on the small sowing board, and finally press the "zero" switch. Install the upper fixture holding the sample, Clamp the lower clamp, then press the "50" gear, and adjust the "fine adjustment" knob to make the reading on the display meter zero. Press the "over-power" switch on the force measuring display meter to set the "range attenuation" And "test speed" and then turn on the recorder's paper feed speed, then press the "down." button on the speed unit panel to test.

After the test of one sample of the force measuring instrument, the operation must be carried out in the following order, and the operation process must be careful and careful.