Filling scale instrument features parameter description
When the filling scale instrument is operating, the operator only needs to simply move the container so that the filling mouth of the container is aligned directly below the nozzle of the spray gun. Press the "Start" button, the spray gun will automatically descend, the empty barrel will be automatically peeled, and thenFilling scale instrumentMulti-speed filling ensures filling accuracy. After filling, the spray gun is automatically lifted to the outside of the barrel. The operator removes the full barrel and a filling cycle ends.
Set up batch and offload time monitoring
Double digital filtering
Provide cumulative totals and lot numbers
It has the functions of rough metering, fine metering or jogging batching, overshoot compensation and so on.
Optional slow start delay time for filling scale meters
Fully automatic 3-speed feed control with selectable jog and jog functions
Full board digital calibration, you can manually input millivolts to complete the calibration (no weight calibration function)
It can store 20 kinds of formulas, which is convenient for the packaging of different range of materials.
The infeed control function facilitates the control connection between the packaging scale and the front-end infeed equipment.
Automatic fall correction function
Multiple digital filtering functions
Setting items: upper limit\/lower limit\/close to zero\/large feed\/pre-dosing\/drop\/over\/short\/dosing
Comparison prohibition time\/judgment time\/final output time\/compensation feed time\/AZ time\/judgment time\/automatic drop compensation value\/
Analog filter\/tare
Filling scale meter measurement function 1\/measurement function 2\/measurement function 3\/sequential mode\/function key prohibition\/digital filter\/dynamic tracking\/zero tracking time\/
Zero tracking amplitude
Weight value\/maximum weight value\/minimum scale\/net weight overload\/gross weight overload\/dz limit value\/function selection\/
Gravitational acceleration compensation (area number input) \/ set point lock \/ tare function limit
Input selection\/output selection\/station number\/baud rate\/station number
Average Weight\/Max\/Min\/Total Standard Deviation\/Sample Standard Deviation\/Number of Data (N)\/Latest Cumulative Data\/
Max Min (right) \/ Palette
Zero adjustment range: 0-2mv\/v, coarse adjustment: digital control according to the coarse adjustment loop; fine adjustment: automatic adjustment method based on numerical calculation
Span adjustment range: 0.3-3.2mv\/v, coarse adjustment: digital control according to the coarse adjustment loop; fine adjustment: automatic adjustment method based on numerical calculation
Minimum input scale: 0.3μv\/tick count
Accuracy: Nonlinear: within 0.01%\/fs. Zero drift: within 0.2μv\/degree Celsius rti; range drift: 15ppm\/degree Celsius
Analog filter: Bessel low-pass filter (-12db\/oct) 2hz, 4hz, 6hz, 8hz optional
When the actual amount is less than the target amount, the allowable amount of ingredients to be added
Equipped with signal output of batching completion and unloading completion.
A real-time clock can be selected to match the printing of the report.
RS485 interface allows multipoint communication
There are 2 independent sets of inhibit comparison times, including startup and fast-to-slow transitions.
Filling scale meter can set the effective range of overshoot compensation
The skin removal delay time can be set.
The number of skin removal samples can be set.
Stator comparison time can be set
The filling scale instrument is suitable for products with low to high viscosity, and the applicable filling volume is from 50L to 1000L, with an accuracy of 2\/1000 (depending on the specifications of the iron drum, product properties and feeding pressure), and also It can be used for 4 200 (2*2) liter drums, 16 plastic drums (4*4) and a 1000L ton package on a pallet.